常用公稱壓力下管道壁厚選用表
材料 PN
MPa DN
10 15 20 25 32 40 50 65 80 100 125 150 200 250 300 350 400 450 500 600
20
12CrMo
15CrMo
12Cr1MoV ≤1.6 2.5 3 3 3 3 3.5 3.5 4 4 4 4 4.5 5 6 7 7 8 8 8 9
2.5 2.5 3 3 3 2 3.5 3.5 4 4 4 4 4.5 5 6 7 7 8 8 9 10
4.0 2.5 3 3 3 3 3.5 3.5 4 4 4.5 5 5.5 7 8 9 10 11 12 13 15
6.4 3 3 3 3.5 3.5 3.5 4 4.5 5 6 7 8 9 11 12 14 16 17 19 22
10.0 3 3.5 3.5 4 4.5 4.5 5 6 7 8 9 10 13 15 18 20 22
16.0 4 4.5 5 5 6 6 7 8 9 11 13 15 19 24 26 30 34
20.0 4 4.5 5 6 6 7 8 9 11 13 15 18 22 28 32 36
4.0T 3.5 4 4 4.5 5 5 5.5
10
Cr5Mo ≤1.6 2.5 3 3 3 3 3.5 3.5 4 4.5 4 4 4.5 5.5 7 7 8 8 8 8 9
2.5 2.5 3 3 3 3 3.5 3.5 4 4.5 4 5 4.5 5.5 7 7 8 9 9 10 12
4.0 2.5 3 3 3 3 3.5 3.5 4 4.5 5 5.5 6 8 9 10 11 12 14 15 18
6.4 3 3 3 3.5 4 4 4.5 5 5.5 7 8 9 11 13 14 16 18 20 22 26
10.0 3 3.5 4 4 4.5 5 5.5 7 8 9 10 12 15 18 22 24 26
16.0 4 4.5 5 5 6 7 8 9 10 12 15 18 22 28 32 36 40
20.0 4 4.5 5 6 7 8 9 11 12 15 18 22 26 34 38
4.0T 3.5 4 4 4.5 5 5 5.5
16Mn
15MnV ≤1.6 2.5 2.5 2.5 3 3 3 3 3.5 3.5 3.5 3.5 4 4.5 5 5.5 6 6 6 6 7
2.5 2.5 2.5 2.5 3 3 3 3 3.5 3.5 3.5 3.5 4 4.5 5 5.5 6 7 7 8 9
4.0 2.5 2.5 2.5 3 3 3 3 3.5 3.5 4 4.5 5 6 7 8 8 9 10 11 12
6.4 2.5 3 3 3 3.5 3.5 3.5 4 4.5 5 6 7 8 9 11 12 13 14 16 18
10.0 3 3 3.5 3.5 4 4 4.5 5 6 7 8 9 11 13 15 17 19
16.0 3.5 3.5 4 4.5 5 5 6 7 8 9 11 12 16 19 22 25 28
20.0 3.5 4 4.5 5 5.5 6 7 8 9 11 13 15 19 24 26 30
『貳』 如何選擇鍍鋅鋼管的壁厚
選擇鍍鋅鋼管的壁厚一般根據鋼管的規格和鋼管的用途來選擇。
『叄』 管道設計壁厚的選擇
採用20#材料,計算厚度2.2mm,腐蝕裕度2mm,可以選用6mm或8mm,比這厚的當然更沒問題。
『肆』 鋼管的壁厚怎麼選擇
鋼管的壁厚是按公稱系列選擇的,其都是以標准件形式存在的。
提供一種目前採用較多的公稱壁厚選擇方法。
以管子表號(Sch.)表示壁厚系列
這是1938年美國國家怔准協會ANSIB36.10(焊接和無縫鋼管)標准所規定的。
管子表號(Sch.)是設計壓力與設計溫度下材料的許用應力的比值乘以1000,並經圓整後的數值。即:Sch .=P/[ó]t×1000
式中 P—設計壓力,MPa; [ó]t—設計溫度下材料的許用應力,MPa。
無縫鋼管與焊接鋼管的管子表號可查資料確定。
ANSI B36.10和JIS標准中的管子表號為;Schl0、20、30、40、60、80、100、120、140、160。
ANSI B36.19中的不銹鋼管管子表號為:5S、10S、40S、80S。
管表號(Sch.)並不是壁厚,是壁厚系列。實際的壁厚,同一管徑,在不同的管子表號中其厚度各異。不同管子表號的管壁厚度,在美國和日本是應用計算承受內壓薄壁管厚度的Barlow公式計算並考慮了腐蝕裕量和螺紋深度及壁厚負偏差-12.5%之後確定的,計算壁厚徑圓整後才是實際的壁厚。
如果已知鋼管的管子表號,可計算出該鋼管所能適應的設計壓力,即
P=Sch..× [ó]t/1000
例如,庫存Sch40,碳素鋼20無縫鋼管,當設計溫度為350oC時給鋼管所能適應 設計壓力為:
P=40×92/1000①=3.68 MPa
『伍』 如何根據管道壁厚確定壓力等級
設計上會針對不同的介質情況作出說明。一般以4.0MPa為界
合理的管壁厚可以按管子表號(Sch.)表示壁厚系列
這是1938年美國國家標准協會ANSIB36.10(焊接和無縫鋼管)標准所規定的。
管子表號(Sch.)是設計壓力與設計溫度下材料的許用應力的比值乘以1000,並經圓整後的數值。即:Sch .=P/[ó]t×1000
式中 P—設計壓力,MPa; [ó]t—設計溫度下材料的許用應力,MPa。
無縫鋼管與焊接鋼管的管子表號可查資料確定。
ANSI B36.10和JIS標准中的管子表號為;Schl0、20、30、40、60、80、100、120、140、160。
ANSI B36.19中的不銹鋼管管子表號為:5S、10S、40S、80S。
管表號(Sch.)並不是壁厚,是壁厚系列。實際的壁厚,同一管徑,在不同的管子表號中其厚度各異。不同管子表號的管壁厚度,在美國和日本是應用計算承受內壓薄壁管厚度的Barlow公式計算並考慮了腐蝕裕量和螺紋深度及壁厚負偏差-12.5%之後確定的,計算壁厚徑圓整後才是實際的壁厚。
如果已知鋼管的管子表號,可計算出該鋼管所能適應的設計壓力,即
P=Sch..× [ó]t/1000
例如,庫存Sch40,碳素鋼20無縫鋼管,當設計溫度為350oC時給鋼管所能適應 設計壓力為:
P=40×92/1000①=3.68 MPa
其中「STD」為標准管壁厚系列代號,「XS」這加強管壁厚系列代號,「XXS」為特加強管壁厚系列代號。
具體的表格數據可參照GB12459-2005的附錄B——無縫鋼管壁厚分級表
『陸』 如何計算鋼管壁厚
焊接鋼管規格表
日期:2010-8-13 作者:劉磊
焊接鋼管規格表:2010-4-19 壁 厚/mm
.5 0.6 0.8 1.0 1.2 1.4 1.5 1.6 1.8 2.O 2.2 2.5 2.8 3.0 3.2 3.5
鋼管的理論質量
焊接鋼管規格表:壁 厚/mm
O.5 0.6 0.8 1.0 1.2 1.4 1.5 1.6 1.8 2.O 2.2 2.5 2.8 3.0 3.2 3.5
鋼管的理論質量/(kg/m)
5 O.055 0.065 O.083 O.099
8 0.092 O.109 O.142 O.173 O.201
10 0.117 O.139 0.181 0.222 0.260
12 0.142 O.169 O.221 O.271 O.320 O.366 O.388 0.410
13 O.183 0.241 0.296 O.343 0.400 O.425 0.450
14 0.198 O.260 O.321 O.379 O.435 O.462 O.489
15 O.123 0.280 O.345 0.408 O.470 O.499 O.529
16 O.228 O.300 O.370 0.438 0.504 O.536 O.568
17 0.243 O.320 O.395 O.468 0.359 O.573 O.608
18 0.257 0.339 O.419 O.497 O.573 0.610 0.647
19 O.272 O.359 0,444 0.527 0.608 O.647 O.687
20 0.287 0.379 O.469 O.556 O.642 O.684 O.726 0.808 0.888
21 0.399 0.493 0.586 0.677 O.721 O.765 0.852 0.937
22 O.418 O.518 O.616 O.7U O.758 O.805 O.897 0.986 1.074
25 O.477 O.592 O.704 0.815 O.869 O.923 1.030 1.134 1.237 1.387
28 O.537 O.666 O.793 0.918 O.980 1.0412 1.163 1.282 1.400 1.572 1.740
30 0.576 O.715 0.852 0.987 1.054 1.121 1.252 1.381 1.508 1.695 1.878 1.997
32 O.764 0.911 1.065 1.128 1.199 1.341 1.480 1.617 1.1819 2.016 2.145
34 O.814 O.971 1.125 1.202 1.278 1.429 1.578 1.725 1.942 2.154 2.293
37 O.888 1.059 1.229 1.313 1.397 1.562 1.726 1.888 2.127 2.361 2.515
外徑
/mm 壁 厚/mm
O.5 0.6 O.8 1.O 1.2 1.4 1.5 1.6 1.8 2.O 2.2 2,5 2.8 3.0 3.2 3.5
鋼管的理論質量/(kg/m)
38 0.912 1.089 1.264 1.350 1.436 1.607 1.776 1.942 2.189 2.430 2.589 2.746 2.978
40 O.962 1.148 1.333 1.424 1.515 1.696 1.874 2.051 2.312 2.569 2.737 2.904 3.150
45 1.09 1.30 1.5l 1.61 1.71 1.92 2.12 2.32 2.62 2.91 3.11 3.30 3.58
46 1.33 1.54 1.65 1.75 1.96 2.17 2.38 2.68 2.98 3.18 3.38 3.668
48 1.38 1.6l 1.72 1.83 2.05 2.27 2.48 2.81 3.12 3.33 3.54 3.84
50 1.44 1.68 1.79 1.91 2.14 2.37 2,59 2.93 3.26 3.48 3.69 4.Ol
5l 1.47 1.71 1.83 1.95 2.18 2.42 2.65 2.99 3.33 3.55 3.77 4.10
53 1.53 1.78 1.90 2.03 2.27 2.52 2.76 3.11 3.47 3.70 3.93 4.27
54 1.56 1.82 1.94 2.07 2.32 2.56 2.81 3.17 3.54 3.77 4.01 4.36
60 1.74 2.02 2.16 2.30 2.58 2.86 3.14 3.54 3.95 4.22 4.48 4.88
63.5 1.84 2.14 2.29 2.44 2.74 3.03 3.33 3.76 4.19 4.48 4.76 5.18
65 2.35 2.50 2.81 3.11 3.41 3.85 4.29 4.59 4.88 5.31
70 2.37 2.70 3.03 3.35 3.68 4.16 4.64 4.96 5.27 5.74
76 2.76 2.94 3.29 3.65 4.00 4.53 5.05 5.40 5.74 6.26
80 2.90 3.09 3.47 3.85 4.22 4.78 5.33 5.70 6.06 6.60
83 3.OI 3.2l 3.60 3.99 4.38 4.96 5.54 5.92 6.30 6.86
89 3.24 3.45 3.87 4.29 4.71 5.33 5.95 6.36 6.77 7.38
95 3.46 3.69 4.14 4.59 5.03 5.70 6.37 6.8l 17.24 7.90
101.6 3.70 3.95 4.43 4.91 5.39 6.11 6.82 7.29 7.76 8.47
102 3.72 3.96 4.45 4.93 5.41 6.13 6.85 7.32 7.80 8.50
『柒』 與鋼管連接的管件壁厚標准怎麼選擇
管件的作用就是連接鋼管,使管道可以改變方向和口徑,管件的壁厚和鋼管的壁厚是一樣的,這樣的話就可以使管件在連接鋼管的時候會有一個合適的介面。所以一般情況下采購的鋼管和管件都是配套的,壁厚也是一樣的